Kick off your Elemental Journey with the essentials: what X‑ray fluorescence (XRF) is, how it works, and where it delivers the most value versus other elemental techniques. Qiaona Zhang and Lieven Kempenaers break down WDXRF vs. EDXRF, sample types (solids, liquids, powders), and why XRF’s speed and non‑destructive nature make it a mainstay from QC labs to R&D.
What you’ll learn
– The XRF principle in plain language—characteristic X‑rays as elemental “fingerprints.”
– WDXRF vs. EDXRF trade‑offs and when to pick benchtop vs. higher‑power systems.
– Why XRF’s speed, repeatability, and non‑destructive workflow fit QC, process control, and R&D.
Want practical XRF tips in your inbox? Subscribe and watch Episode 2 on calibration next.
00:00 Introduction
00:25 Meet the Presenters
00:45 What Is XRF?
01:23 How XRF Works (The Principle)
02:36 Key Benefits of XRF
03:44 Where XRF Is Used
05:00 The XRF Technology Family (WDXRF & EDXRF)
08:28 Choosing the Right XRF System
09:48 Benchtop vs Floor-standing Systems
10:23 Summary & Wrap-up
Also follow us on:
https://www.instagram.com/malvernpanalytical/
https://www.linkedin.com/company/malvernpanalytical
#XRF #MaterialAnalysis #LabTips #QualityControl #MalvernPanalytical
Not all XRF is “absolute.” In this episode, Qiaona Zhang and Lieven Kempenaers explain why calibration matters, how to build one that matches your matrix, and when a “standardless” screening approach is useful for indicative results. You’ll learn how standards, prep routes (pressed vs. fused), and consistent procedures turn intensities into trustworthy concentrations.
What you’ll learn
– Why XRF is comparative and needs matrix‑matched standards.
– Conventional calibrations vs. universal/screening (“standardless”) analyses—pros and cons.
– Why matching sample prep between standards and unknowns is critical for reproducibility.
Next up: sample preparation—the #1 source of XRF error and how to control it. Subscribe to catch Episode 3
00:00 Welcome & Introduction
00:12 Why XRF Needs Calibration
00:42 XRF as a Comparison Technique
01:06 Two Calibration Methods (Conventional vs Screening)
01:59 Choosing the Right Calibration Standards
02:23 How Calibration Lines Are Built
03:12 Matching Prep Between Standards & Samples
03:49 Running an XRF Measurement After Calibration
04:18 Conventional Calibration: Pros & Cons
04:42 Standardless / Screening XRF Explained
05:49 Using Both Approaches Together
06:02 Summary & Next Episode Teaser